LEYI® Ceramic Crown · Ceramic crown resin for 3D printing

HC-Crown Ceramic Crown Resin

56% nano-ceramic filler for high-strength crowns and other long-term restorations.

  • Nano-ceramic56%
  • Flexural strengthUp to 200 MPa
  • Shore hardness90–95 D
  • ShadesBL/A1/A2/A3
HC-Crown Ceramic Crown Resin bottle with 3D printed crowns and bridges

HC-Crown is LEYI’s ceramic crown resin for 3D printing high-strength ceramic crowns and other long-term restorations, including veneers, single crowns, inlays, long-span bridges and implant bridges. The ceramic-filled formula contains 56% nano-ceramic, with flexural strength of 175–200 MPa (up to 200 MPa) and Shore hardness of 90–95 D. It resists wear, corrosion and staining, and it’s radiopaque. Available in BL, A1, A2 and A3 for 385–405 nm printers; print with the resin heated to 35°C.

HC-Crown key benefits

  • BiocompatibleAs stated in product documentation and on the bottle label
  • Flexural strength up to 200 MPaHandles bite loads, resists fracture
  • High wear resistanceSurface holds up over long-term use
  • Strong corrosion resistanceResists corrosion and staining
  • RadiopaqueEasy to identify on X-rays
  • Natural tooth lookLifelike esthetics
  • Anti-settlingStays uniform despite high ceramic content
  • No odorA more pleasant workspace

HC-Crown Indications

For high-strength restorations built to last

  • HC-Crown 3D printed veneer

    Veneers

  • HC-Crown 3D printed single crown

    Single crowns

  • HC-Crown 3D printed inlay

    Inlays

  • HC-Crown 3D printed long-span bridge

    Long-span bridges

  • HC-Crown 3D printed implant bridge

    Implant bridges

HC-Crown 3D printed three-unit bridge on a dental model

HC-Crown Strong and fracture-resistant

Flexural strength of 175–200 MPa (up to 200 MPa) and flexural modulus of 6500–7500 MPa give restorations high bite-load capacity and fracture resistance.

Polished HC-Crown crowns and veneers

HC-Crown Resists wear, corrosion and staining

High resistance to wear, corrosion and staining, with lifelike esthetics that look like natural teeth.

HC-Crown Four tooth shades

BL, A1, A2, A3. Pick the shade the case calls for

HC-Crown crowns 3D printed in BL, A1, A2 and A3
  • BL (bleach)
  • A1
  • A2
  • A3

Swatches are for illustration only. Confirm shade against a physical sample. Sizes: 0.5 kg/bottle, 1 kg/bottle.

Close-up of an HC-Crown three-unit bridge seated on a dental model123

HC-Crown Accurate prints that polish easily

High print accuracy, and printed crowns polish easily to a natural, lifelike finish.

  1. 1Contact points
  2. 2Marginal fit
  3. 3Occlusal fissures

HC-Crown Real X-ray images

Photos of intraoral X-rays: the crown restorations show up clearly, so they’re easy to identify on images and at follow-up visits.

HC-Crown single crown on an intraoral X-ray
Single crown · intraoral X-ray
HC-Crown bridge on a periapical X-ray
Bridge · periapical X-ray

Images are photos of clinical X-rays taken from a screen.

HC-Crown Product video

Product video for HC-Crown Ceramic Crown Resin, showing printing and finished restorations (English subtitles).

HC-Crown Print and post-processing workflow

HC-Crown workflow: shake and preheat

01 Shake and preheat

Shake for 1–2 min before use, or mix thoroughly for about 15 min. Heat the printer to 35°C or higher so the high-viscosity resin flows well.

HC-Crown workflow: print crowns and bridges

02 Print crowns and bridges

On LEYI printers, just select the HC-Crown profile. On other printers, start from our technicians’ recommended settings and test-print a representative crown first.

HC-Crown workflow: wipe clean

03 Wipe clean

Wipe the part surface with a nonwoven cloth dampened with IPA.

HC-Crown workflow: post-cure both sides

04 Post-cure both sides

High-power curing unit: 7 min UV per side. Low-power curing unit: 35 min UV per side.

HC-Crown workflow: finish and polish

05 Finish and polish

Parts polish easily to a natural, lifelike finish.

HC-Crown Specifications and technical data

Product specifications

ShadesBL, A1, A2, A3
Packaging0.5 kg/bottle, 1 kg/bottle
Wavelength385–405 nm
CleaningWipe with IPA-dampened nonwoven cloth
Post-cureHigh power 7 min per side / low power 35 min per side
ApplicationsVeneers, single crowns, inlays, long-span bridges, implant bridges
StorageUnopened: 10–30°C, away from light; shipping: 0–45°C
Shelf life36 months

Technical data

Nano-ceramic content—56%
Viscosity (25°C)ISO 32197800–8300 mPa·s
Shore hardnessISO 86890–95 D
Flexural strengthISO 178175–200 MPa
Flexural modulusISO 1786500–7500 MPa

Recommended print settings

Wavelength385–405 nm
Print temperaturePrinter heated to 35–45°C
Ambient humidity≤50%
Layer thickness0.05 mm
Exposure timeLow intensity 2–4 s; high intensity 2.8–3 s
Bottom layers / exposureLow intensity 5 layers / 25 s; high intensity 3 layers / 8 s
Recommended printers6 in or smaller printers

Print settings from the HC-Crown TDS v2.0. If you change printer, layer thickness or post-cure conditions, re-tune the settings and verify on real crowns.

Want to verify these settings on your own printer and crown and bridge cases?

Request a sampleGet a quote →
LEYI resin inner box and outer shipping carton

HC-Crown Packaging

0.5 kg/bottle, 1 kg/bottle. Shake before use. After opening, close the cap tightly and store sealed, away from light.

FAQ

HC-Crown FAQ

What restorations can I make with HC-Crown?

HC-Crown is for high-strength ceramic crowns and other long-term restorations, including veneers, single crowns, inlays, long-span bridges and implant bridges. Availability and regulatory status vary by country. Contact us to confirm indications for your market.

What is the ceramic content and strength of HC-Crown?

HC-Crown contains 56% nano-ceramic, with flexural strength of 175–200 MPa (ISO 178, up to 200 MPa), flexural modulus of 6500–7500 MPa and Shore hardness of 90–95 D.

What shades are available?

BL, A1, A2 and A3. On-screen swatches are for illustration only; confirm shade against a physical sample.

Why heat the printer to 35°C?

Because of its high ceramic content, HC-Crown has a viscosity of 7800–8300 mPa·s at 25°C. Heating the printer to 35°C or higher improves flow and print success. The TDS recommends a printer temperature of 35–45°C and ambient humidity of ≤50%.

How do I clean printed crowns?

Wipe the part surface with a nonwoven cloth dampened with IPA. Don’t soak parts in IPA, or a white powder may form on the surface.

How should I post-cure?

High-power curing unit: 7 min UV per side. Low-power curing unit: 35 min UV per side. Curing power affects the color and strength of ceramic crowns; a high-power unit gives stronger crowns and more accurate color.

How is HC-Crown different from DTIC02 Temp C&B Resin?

HC-Crown contains 56% nano-ceramic and reaches 175–200 MPa flexural strength, for long-term restorations. DTIC02 contains no nano-ceramic, has a flexural strength of 70–85 MPa, and is for temporary crowns, temporary implant bridges and other provisionals.

How do I request a sample or a quote?

Submit a sample request with your restoration type, printer model, light source wavelength and expected volume. For pricing, MOQ and lead time, contact our sales team.

Choosing a LEYI crown and bridge resin

HC-Crown for long-term restorations, DTIC02 for temporaries.

  • Crowns and bridges 3D printed in HC-Crown
    HC-Crown

    Ceramic Crown Resin

    Veneers, single crowns, inlays, long-span bridges, implant bridges and other long-term restorations

    Nano-ceramic content
    56%
    Flexural strength
    175–200 MPa
    Viscosity (25°C)
    7800–8300 mPa·s
    Current product
  • Temporary crowns and bridge 3D printed in DTIC02
    DTIC02

    Temp C&B Resin

    Single crowns, implant provisionals, temporary implant bridges

    Nano-ceramic content
    None
    Flexural strength
    70–85 MPa
    Viscosity (25°C)
    1000–1400 mPa·s

Data from LEYI product documentation (October 2026). Actual values vary with printer and post-cure conditions.

Further reading: Temporary vs. ceramic crown resins HC-Crown fact sheet How post-curing affects properties Resin and printer compatibility check

Test HC-Crown on your own crown and bridge cases

Tell us your printer and the restorations you make most. We’ll send a sample with matching print settings.

Hangzhou Leyi New Material Technology Co., Ltd. Founded in 2015, we develop and manufacture photopolymer resins for 3D printing.