How should I wash dental models after printing?

Remove the part, let it drain, wash in stages, dry and inspect. Follow the product documents for the wash solvent and times.

Quick answer

The goal of washing a dental model is to remove surface resin without over-soaking, scrubbing hard or post-curing before the part is dry. Let excess resin drain first, then wash as the product documents specify, dry the model and check fine detail and holes.

1. Drain excess resin after removal

Wear appropriate PPE. Remove the part from the build platform as instructed and let surface resin drain back fully. Keep uncured resin off your skin and work surfaces.

2. Choose a wash method from the product documents

Confirm the wash solvent, number of washes, equipment and time. A two-stage wash works well: a first bath for most of the resin, then a clean final rinse. Don’t keep using solvent once it’s heavily contaminated.

3. Dry thoroughly after washing

Check cusps, holes, the base and support contact points for leftover resin. Don’t post-cure until the part is dry inside and out.

4. Inspect before post-cure

Look for tacky or white surfaces, leftover liquid or damage. If supports need to come off, follow the sequence for that workflow. Post-cure as the product specifies only after everything checks out.

Related questions

Does a longer wash get models cleaner?

No. Over-soaking can affect the surface or dimensions. Use the solvent and time specified in the product documents.

Why does my model turn white after washing?

It may be related to the condition of the wash solvent, leftover resin, drying or the resin’s process. Keep photos and a full post-processing record, and check each factor one at a time.

This article describes a general method. For specific settings, follow the current TDS, SDS and IFU for the product and your own test prints.

More in this category

Having an issue? Note the symptom, printer model and resin model, then Contact support.